-
Исследуя призма рефлектора
-
Призма обзора мини
-
Призма 360 градусов
-
полная призма станции
-
Поляк Bipod призмы
-
поляк волокна углерода телескопичный
-
Телескопичный выравнивая штат
-
Переходник Tribrach
-
Треноги аппаратуры
-
Полные батареи станции
-
Полный заряжатель батареи станции
-
Полный кабель станции
-
Полные аксессуары станции
-
Исследуя аппаратура
Topcon Battery BT-G1W for Topcon Total Station GTS-330 GTS-3000
Напряжение тока | 7.2V | Емкость | 2700мАх |
---|---|---|---|
Размер | 140*80*35mm | Тип | НИ-МХ |
Вес | 350g | Заряжатель | Because-27CR |
Поручая время | 2 часа | Температура | °C 10~40 |
Условие | Новый | Цвет | желтый |
Topcon Battery BT-G1W for Topcon Total Station GTS-330 GTS-3000
Model: BT-G1W
Specifications:
Voltage | 7.2V |
Dimension | 140*80*35mm |
Type | Ni-Mh |
Capacity | 2700mAh |
Weight | 350g |
Package | Individual Box Package |
Warranty | 1 Year |
Temperature | 10~40 °C |
Charger | BC-27CR |
Charging Time | 2 Hours |
Rechargeable | Yes |
Used For | TOPCON GTS-250/330/3000 Total Station |
Highlights
- For Topcon GST-250 Series Total Station
- 9-hour battery life when measuring distances
- 40-hour battery life when measuring angles
- Protected against short circuit, overcharging & overheating
- Rechargeable NiMH
- 2-hour charging time
- 2700 mAh, 7.2V
Overview:
Durable and safe, the Topcon BT-G1W Rechargeable NiMH Battery is the best battery pack for the Topcon GTS-250 Series Total Station. It is a 7.2-volt NiMH type battery with a 2700 mAh capacity. It features stable circuitry and protection against short circuit, overcharging and overheating.
The Topcon BT-G1W battery only takes two hours to fully charge and keeps the total station operational up to nine hours when taking distance measurements. When only measuring angles, this battery can keep the total station working up to 40 hours.
New and stored batteries
New NiCd and NiMH batteries reach their maximum capacity only after a few charging and discharging cycles. The batteries should be fully discharged and charged three to five times. NiMH batteries that have been stored and not used for an extended period (more than a month) should be refreshed simularly. For Li-Ion batteries, a single discharging and charging cycle is sufficient.
Batteries in regular use
After use the battery can be placed in the charger until fully charged (the green light flashes). The charging time depends on the battery capacity and temperature.
Charging temperature
The charging temperature (ambient temperature) has a significant impact on the life of the batteries. Charging at high temperature can cause loss of capacity. These losses in capacity are irreversible. Even with several charging and discharging cycles, the original capacity can no longer be obtained. For optimal charging, we recommend that the batteries be charged at ambient temperatures as low as possible (+10 °C to +20 °C / +50 °F to +68 °F). The permitted temperature range in which charging can still be performed is between 0 °C and +35 °C (+32 °F and +95 °F).